Aquatic Technology Pool & Spa, "Creating Water as Art."™

Aquatic Technology Pool & Spa, "Creating Water as Art."™
Pools as an art form - the way it should be!

Wednesday, May 23, 2012

Infinity & Vanishing Edge Pools - Preventing Leaky Weir Walls

Infinity and Vanishing Edge Pool Walls - Stopping the drips

I've had a number of requests for the addition of some graphics to help readers visualize the infinity edge weir wall and basin relationships.

The graphics will be hand drawings and not our usual computer drawings.  It is our intent to help you understand the concepts and not to provide a "cut and paste" work product on the Internet.

Where does the waterproofing go?

Since the vanishing edge wall is in effect a freestanding dam, it makes sense to incorporate waterproofing within the cement of the wall.  No matter what remodeling or work occurs in the future, there will always be that non-corruptible layer of protection.

I specify an additional layer of protection on the both surfaces of the wall, as well as inside the entire basin.  Any tile or stonework on the "dry side" of the vanishing edge wall or lining the catch basin, should extend down and into the minimum operating level of water that always remains (MOL).  Because the water level in the basin is constantly changing, the walls above the MOL are subject to constant wetting & drying.   Therefore any plaster based finish will be subject to shrinkage cracking.

The yellow highlighted area illustrates the minimum areas that should receive a topical waterproofing.  I prefer an elastomeric membrane topped with a compatible skimcoat of thinset (products from the same manufacturer).  This will ensure that the plaster will bond on the inside of the pool.  This membrane also prevents any moisture from intruding into the wall, since plaster is not waterproof.  Yes, you read that correctly, plaster is not waterproof.  It is after all, just cement and sand - and water does wick through cement based products.

 The yellow highlights indicate the minimal areas of waterproofing required.

Which way to tilt the weir?

It is a matter of preference.  I prefer to tilt the weir down and into the pool.  It creates the illusion that the pool is slightly larger than it actually is.

It is a fact of physics that water will always seek level.  It is also true that water will migrate via capillary action through cement.  If no waterproofing is employed on the vanishing edge wall, then water (2 large arrows on left) will quickly begin to seep through the mortar bed (green).

No matter which way the weir tilts, since the water level in the pool is higher than the potential exit point on the dry side, hydraulic pressure (weight) and gravity will force the water to pass through the mortar.  Left unchecked, over time the water in the pool would equalize with the exit point on the dry side of the wall (indicated by the blue line & double headed arrows to the right of the weir). 

Purple -  Granite tiles/slab
Green -   Mortar leveling bed
Pink -     Interior plaster/tile finish
Yellow - Dry side VE wall tile
Blue -     Water & migration paths
Blue Line - Equalization level

The water then migrates through the mortar bed, behind the dry side tiles.  As the water discovers cracks in the grout, some exits carrying with it dissolved salts (efflorescence).  The water will continue to flow through this mortar or in hollow areas behind the tiles, until it either encounters a dense area of mortar or a sound area of tile.  The remaining water will exit at this lower elevation, carrying with it a majority of the dissolved salts (hence a greater build up of efflorescence). (see the prior article on efflorescence).

By incorporating waterproof additives into the mortar bed, one can effectively seal the capillaries in the mortar, thereby retarding water migration.  The addition of a membrane a top the mortar bed, only leaves the layer of thinset (under the granite and tiles) as a possible migration path for the water.

Disclaimer:

The reinforcing shown in the drawings is not intended to represent the actual steel schedules one would utilize.  Instead, they are shown so that you understand how this all goes together.  However, the actual vanishing edge wall should never be less than 12 inches thick with double curtains of steel.  The exact wall thickness, steel size, spacing and placement is determined by the structural engineer.

The catch basin elevations were drawn arbitrarily.  Based upon a projects needs, the catch basin could be above, below or even with the pool floor.  The catch basin could even cantilever in mid-air.

Deepened keyway footings are shown in a drawing, but not every vanishing edge pool requires them.  Some require more elaborate foundations and others no specialized foundation.  The geotechnical engineer will outline this in his soils report for the structural engineer.

Paolo Benedetti - Aquatic Artist
"Creating water as art."™
Aquatic Technology Pool and Spa
©www.aquatictechnology.com

Monday, May 21, 2012

Reverse Osmosis Swimming Pool Water Purification

Swimming Pool Water Purification with Reverse Osmosis - Playing with Fire

Sanitizing your vanishing, negative or infinity edge swimming pool or spa with a Reverse Osmosis filtration system can have potentially devastating effects on any product that contains cement, minerals or metals.

Understand Water Chemistry

People who market "gimmicks" to the swimming pool industry, oftentimes come from other industries.  They have a "brainstorm" about how they might enlarge their markets, and enter new markets without "doing their homework."

The manufacturers of Reverse Osmosis filtration systems who market to the swimming pool industry and pool owners, simply did not understand the complex dynamics of swimming pool water chemistry. 

It's all about "the Balance"

Swimming pool water needs to be maintained in a complex balance of sanitizers, pH, alkalinity, and minerals.  If any of these get out of balance with the others, the water will seek to create it's own balance.

Potential damage to cements, thinsets, grouts or plaster can easily occur, even though the water chemistry readings appear normal.

It's Got to Come from Somewhere

Let's assume that a new pool had the water balanced prior to a Reverse Osmosis system being activated.  The water contained 300 parts per million (ppm) of calcium.

When the Reverse Osmosis system is brought on-line, it immediately attempts to remove EVERYTHING from the water.  This includes anything dissolved in the water: sanitizer (chlorine/bromine), minerals, metals, calcium...

Eventually, the calcium level drops in the pool water to the equilibrium point.  At this point, if the calcium level drops any lower, the water will begin to seek alternative sources of calcium to maintain that equilibrium.

So, begins the degradation of any material in constant contact with the water that contains calcium, minerals or metals.  Testing the water will indicate that the levels are okay.  What the test cannot and does not indicate, is the SOURCE of the calcium, minerals or metals.

As make up water is introduced to the pool from the fill line, alternative minerals are introduced.  These may be drawn out of the make-up water & into the plaster.  The plaster is attempting to re-balance itself with alternative minerals... and the plaster begins to degrade.  The plaster may begin to stain, soften, crumble or dust.

Metallic objects in contact with the water may also be "attacked" by this imbalance. The copper within the pool heater, heat pump or solar panels may begin to corrode.  The soft copper is easily attacked by aggressive water.  These components will begin to get thinner & thinner until they begin to leak.  This is why R.O. systems within a house are plumbed with only plastic tubing... the R.O. treated water will actually eat copper lines.

Issue caused by the Builder/Specifier

The responsibility of any resulting damage belongs to the pool builder or party that specified or installed the Reverse Osmosis Purification System.  A pool service company has no means to verify the source of balancing components of the pool water.  It simply is not a "service company" problem.

These units are installed as a side-stream purification system.  They work in parallel with the primary filtration system.  So, they are removing minerals from the water faster that the minerals are being replaced.  Eventually the equilibrium point is reached & the water begins to extract minerals from any alternative source it can.

NO TEST exists that can determine the SOURCE of the minerals present in the water, so the damage continues unchecked... until visible damage has already occurred.   The first sign is usually mineral staining or crumbling grout.

If the system only treated the fill (make-up) water, then the dilution of the pool water may never reach the equilibrium point.  This is because as water evaporates, the minerals are left behind.  The mineral concentration increases from evaporation, while the R.O. treated water with zero minerals, dilutes the remaining water.  This is not to say that the equilibrium point would never be reached.  It all depends on how fast the minerals concentrated & how fast they were removed.

But, because the R.O. system is only treating the make-up water and not treating the entire pool when ever the filtration system is running, the calcium levels tend to stay high.

This same situation can occur by installing a water softener on the make-up water line.  In areas with extremely high mineral levels in the drinking water, a water softener on the fill line will help keep the pool water from becoming so hard that calcium deposits develop everywhere (hard water spots or a line on the waterline tiles).

Don't buy into a program because of a company or salesman's pitch.  A builder or specifier needs to understand how the system works, how it effects the water chemistry and any potential detrimental effects it may cause to the project.

One way to enjoy Reverse Osmosis water

The only way to safely enjoy reverse osmosis water in your swimming pool... is to drink a glass of it while floating in the pool.

It is virtually impossible to create a pool that does not contain SOME metal components.  Even a vinyl liner pool with plastic pipes & pumps would contain metal in the heaters, fixture screws, handrails and pump shaft seals - there is going to be metal in contact with the water.  And water without ANY MINERALS is like a giant wild hog... constantly looking for something to eat.  And it will not stop until is is satisfied...

R.O. systems utilized for drinking water in a household are fabricated with plastic tubing, fittings and ceramic faucet seals.  No metal is in contact with the R.O. water until it actually passes through the faucet spout... the last 3-4 inches before entering your glass (not long enough to dissolve the faucet).

You sold it... you own it!  

Any damages cause by this type of equipment is the responsibility of the builder/specifier and manufacturer.  The pool builder/specifier will need to repair any resulting damages and the manufacturer will be financially liable for those repairs.


Paolo Benedetti - Aquatic Artist
"Creating water as art."™
Aquatic Technology Pool & Spa